Contact
AL/XLPE/STA/PVC XLPE Insulated Cable
NA2XBY cable is suitable for AC 50Hz power and distribution lines with rated voltage of 600/1000V, which can be used
· in fixed industrial power applications
· Underground tunnels
· in power and switching stations
· local energy distributions
· industrial plants
Using steel tape armouring offers great mechanical protection, making it rigid with a large radius in installation indoors and outdoors.
For any more information or advice please contact the office on 0086-13229065196(WhatsApp/WeChat)
Details
Description: NA2XBY, XLPE Insulated Aluminum Power Cable
Conductors:Class 1 or Class 2 of plain aluminum,or of Class 5 of plain aluminum in accordance with IEC 60228.
Insulation:Cross-linked polyethylene XLPE
Insulation Colour:Natural or as required
Filler: Non-hygroscopic Material
Inner Sheath: Polyvinyl Chloride PVC
Outer Sheath:Extruded Polyvinyl Chloride PVC&Polyethylene PE&LSZH
Colour of Sheath: Black
Voltage Rating (Uo/U):600/1000V
Test Voltage: 3.5kV for 5 minutes
Physical Properties
Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)
Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)
Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)
Technical Data
0.6/1kV-3+1core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight | Max.D.C resistance of conductor(20℃) | Current carrying capacity | |
mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
3X4+1X2.5 | 0.7/0.7 | 0.2 | 1.8 | 15.5 | 318 | 7.41/12.1 | - | 30 |
3X6+1X4 | 0.7/0.7 | 0.2 | 1.8 | 16.8 | 371 | 4.61/7.41 | - | 38 |
3X10+1X6 | 0.7/0.7 | 0.2 | 1.8 | 19.3 | 478 | 3.08/4.61 | 50 | 47 |
3X16+1X10 | 0.7/0.7 | 0.2 | 1.8 | 22.1 | 615 | 1.91/3.08 | 64 | 62 |
3X25+1X16 | 0.9/0.7 | 0.2 | 1.8 | 25.1 | 794 | 1.2/1.91 | 86 | 78 |
3X35+1X16 | 0.9/0.7 | 0.2 | 1.8 | 26.8 | 926 | 0.868/1.91 | 105 | 94 |
3X50+1X25 | 1/0.9 | 0.2 | 1.9 | 30.2 | 1175 | 0.641/1.2 | 125 | 110 |
3X70+1X35 | 1.1/0.9 | 0.2 | 2.0 | 35.1 | 1570 | 0.443/0.868 | 165 | 135 |
3X95+1X50 | 1.1/1.0 | 0.5 | 2.2 | 40.4 | 2359 | 0.32/0.641 | 200 | 160 |
3X120+1X70 | 1.2/1.1 | 0.5 | 2.3 | 45 | 2886 | 0.253/0.443 | 235 | 185 |
3X150+1X70 | 1.4/1.1 | 0.5 | 2.5 | 49.1 | 3396 | 0.206/0.443 | 270 | 205 |
3X185+1X95 | 1.6/1.1 | 0.5 | 2.8 | 54.3 | 4070 | 0.164/0.32 | 310 | 235 |
3X240+1X120 | 1.7/1.2 | 0.5 | 2.8 | 59.1 | 4855 | 0.125/0.253 | 365 | 260 |
3X300+1X150 | 1.8/1.4 | 0.5 | 3.0 | 66 | 6028 | 0.1/0.206 | 420 | 290 |
0.6/1kV-4+1core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight | Max.D.C resistance of conductor(20℃) | Current carrying capacity | |
mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
4X4+1X2.5 | 0.7/0.7 | 0.2 | 1.8 | 16.3 | 365 | 7.41/12.1 | - | 30 |
4X6+1X4 | 0.7/0.7 | 0.2 | 1.8 | 17.7 | 429 | 4.61/7.41 | - | 38 |
4X10+1X6 | 0.7/0.7 | 0.2 | 1.8 | 20.3 | 561 | 3.08/4.61 | 50 | 47 |
4X16+1X10 | 0.7/0.7 | 0.2 | 1.8 | 24 | 728 | 1.91/3.08 | 64 | 62 |
4X25+1X16 | 0.9/0.7 | 0.2 | 1.8 | 28.1 | 974 | 1.2/1.91 | 86 | 78 |
4X35+1X16 | 0.9/0.7 | 0.2 | 1.9 | 29.6 | 1134 | 0.868/1.91 | 105 | 94 |
4X50+1X25 | 1/0.9 | 0.2 | 2.0 | 34 | 1505 | 0.641/1.2 | 125 | 110 |
4X70+1X35 | 1.1/0.9 | 0.5 | 2.2 | 40.3 | 2351 | 0.443/0.868 | 165 | 135 |
4X95+1X50 | 1.1/1.0 | 0.5 | 2.3 | 44.8 | 2907 | 0.32/0.641 | 200 | 160 |
4X120+1X70 | 1.2/1.1 | 0.5 | 2.6 | 50.2 | 3588 | 0.253/0.443 | 235 | 185 |
4X150+1X70 | 1.4/1.1 | 0.5 | 2.8 | 54.6 | 4215 | 0.206/0.443 | 270 | 205 |
4X185+1X95 | 1.6/1.1 | 0.5 | 2.9 | 60.5 | 5133 | 0.164/0.32 | 310 | 235 |
4X240+1X120 | 1.7/1.2 | 0.5 | 3.0 | 67.1 | 6289 | 0.125/0.253 | 365 | 260 |
4X300+1X150 | 1.8/1.4 | 0.5 | 3.2 | 73.7 | 7544 | 0.1/0.206 | 420 | 290 |
0.6/1kV-3+2 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight | Max.D.C resistance of conductor(20℃) | Current carrying capacity | |
mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
3X4+2X2.5 | 0.7/0.7 | 0.2 | 1.8 | 16.6 | 354 | 7.41/12.1 | - | 30 |
3X6+2X4 | 0.7/0.7 | 0.2 | 1.8 | 18 | 416 | 4.61/7.41 | - | 38 |
3X10+2X6 | 0.7/0.7 | 0.2 | 1.8 | 20.9 | 531 | 3.08/4.61 | 50 | 47 |
3X16+2X10 | 0.7/0.7 | 0.2 | 1.8 | 24 | 694 | 1.91/3.08 | 64 | 62 |
3X25+2X16 | 0.9/0.7 | 0.2 | 1.8 | 28.1 | 920 | 1.2/1.91 | 86 | 78 |
3X35+2X16 | 0.9/0.7 | 0.2 | 1.9 | 29.6 | 1034 | 0.868/1.91 | 105 | 94 |
3X50+2X25 | 1/0.9 | 0.2 | 2.0 | 34 | 1400 | 0.641/1.2 | 125 | 110 |
3X70+2X35 | 1.1/0.9 | 0.5 | 2.2 | 40.3 | 2153 | 0.443/0.868 | 165 | 135 |
3X95+2X50 | 1.1/1.0 | 0.5 | 2.3 | 44.8 | 2658 | 0.32/0.641 | 200 | 160 |
3X120+2X70 | 1.2/1.1 | 0.5 | 2.5 | 50.2 | 3329 | 0.253/0.443 | 235 | 185 |
3X150+2X70 | 1.4/1.1 | 0.5 | 2.6 | 54.6 | 3790 | 0.206/0.443 | 270 | 205 |
3X185+2X95 | 1.6/1.1 | 0.5 | 2.8 | 60.5 | 4575 | 0.164/0.32 | 310 | 235 |
3X240+2X120 | 1.7/1.2 | 0.5 | 3.0 | 67.1 | 5564 | 0.125/0.253 | 365 | 260 |
3X300+2X150 | 1.8/1.4 | 0.5 | 3.2 | 73.7 | 6801 | 0.1/0.206 | 420 | 290 |